Can't Find Your Part? Enter Your NSN or PART Number Here:

Last Modified: Mar 19, 2019

NSN 5925-00-001-5942 Circuit Breaker

MFG Part Numbers: D6760-17-10, BACC182L10A, 6752-304-10

Cross Reference Parts for NSN 5925-00-001-5942

MFG Part Number ISC RNVC RNCC HCC MSDS SADC DAC

D6760-17-10

2 2 5 5

BACC182L10A

2 9 5 E

6752-304-10

2 2 3 5

Request A Quote

Part:
Qty:
Email:

Part Information for NSN 5925-00-001-5942 (5925000015942)

Item Name: CIRCUIT BREAKER
Federal Supply Class (FSC): 5925
NIIN: 00-001-5942 (000015942)
Definition: A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
NMF Description: FUSES NOI IN BOXES

Item Specifics

Federal Supply Class (FSC)
Circuit Breakers
Actuator Function
Trip-reset CPRW
Actuator Position Designation
At pole two CPRX
Body Height
2.125 inches maximum ADAU
Body Length
2.200 inches maximum ADAQ
Body Style
Multipole-single actuator type AAQL
Body Width
2.250 inches maximum ADAT
Bushing Length
0.220 inches minimum and 0.280 inches maximum ABXD
Case Material
Plastic ADTV
Center To Center Distance Between Terminals Parallel To Length
1.471 inches minimum and 1.501 inches maximum AEBP
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.751 inches maximum AEBQ
Circuit Protection Type
Overcurrent all locations CPRH
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.780 inches minimum and 1.840 inches maximum AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.751 inches maximum AEHA
Frequency In Hertz
400.0 all locations FREQ
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations CPLM
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations CPRG
Mounting Facility Type And Quantity
6 threaded hole AXHR
Nominal Thread Size
0.138 inches CQJX
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations CPRF
Fragility Factor
Moderately rugged AFJN
Precious Material
Silver PRMT
Storage Type
General purpose warehouse BBRG
Unpackaged Unit Weight
0.500 pounds PKWT
Inclosure Protection Type For Which Designed
General purpose CQXF
Internal Trip Release Configuration
Series trip all locations CPSM
Main Contact Tripping Mechanism Type
Trip free CPRR
Manual Actuator Type And Quantity
1 push-pull CPRT
Reset Method
Manual CPRQ
Pole Quantity
3 AKPX
Precious Material And Location
Terminal surfaces silver PMLC
Terminal Type And Quantity
6 screw TTQY
Test Data Document
81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) TEST
Thread Quantity Per Inch
32 CMLP
Thread Series Designator
Unc THSD
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations CQWN
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations CRCF
Trip Release Characteristic
Time delay all locations CPRL
Trip Release Method
Thermal all locations CPRJ
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations CPRN

Trade Control Compliance Schedule B Export Code: A ten position numeric code that identifies an item exported overseas. this unique identification code is assigned by the U.S. Census Bureau.

Schedule B Sch. B Description Demilitarization Classification ITAR Regulation
8536200040 Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9). Unclassified Not ITAR Controlled

MOE / End Users Represents the subdivisions of a US governmental organization or an agency of the North Atlantic Treaty Organization (NATO), and other friendly governments and international organizations participating in the federal catalog program.

Country / Entity Name MOE
Defense Logistics Agency
Defense Logistics Agency ZZ

Material & Special Handling Item material and handling information

Code Description Value Meaning
HMIRS P Indicates there is no information in the hmirs. the nsn is in a fsc in table ii of fed std 313 and a msds may be required by t
Precious Metals Indicator S Item contains silver.
Criticality Code X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

National Motor Freight NMFC: A six position numeric code, which divides articles into groups or classes according to physical characteristics. The classification is based on truckloads vs. less than truckload.

Code Description Code Value Meaning
NMF Description NMFC 061300 Circuit Breaker/switch Noi
Less than a truck load rating LTL P 77.5
Water Commodity WCC 658 Electrical appliances, small
Type of Cargo TCC Z No special type of cargo code applicable
Special Handling SHC 9 Other or no special handling required (sh)
Air Dimension Code ADC A Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity ACC H Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
Air Special Handling ASH Array No special handling required.

Item Identification | Circuit Breakers

5925-00-001-5942, A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Supply Class (FSC)NSN AssignmentNIINItem Name Code (INC)
5925 Sep 29, 1972 000015942 00136 (Circuit Breaker)

Circuit Breakers Cross Reference

BACC182L10A Cage Code 81205
6752-304-10 Cage Code 82647
D6760-17-10 Cage Code 82647

Codes

COUNTRY CODE: 00
CIIC: U
DML: A
HMIC: P
MGMT CTRL: SF9EH-N
SOS: SMS
INC: 136
WEAPON SYSTEM: JOINT STARS TARGET RADAR SYSTEM
AAC: J
CRITL CODE: X
DEMIL CODE: A
S A: DS
MGMT CTL: SF9EH-N
NIIN ASGMT: 29-SEP-72
QUP: 0
SLC: 0
UI: EA
CAGE: 82647
RNCC: 5
RNVC: 2

Management

Air Force Flag

Air Force

Fund SF – Stock fund applicable to items managed for the air force by the respective inventory control point.
Budget 9 – Air force decentrally managed
Material Management EH – Electronic components (engineering support at the 88th ose/oss)
Price Validation N – The current standard price in the catalog management data (cmd) has not been analyzed or coded for lp/lm. -the price has not been analyzed or reviewed for accuracy. -zop or standard price challenges are permissible, but must be supported with adequate justification. however, if coded for local purchase (lp) or fabrication/manufacture as indicated with an (lm) acquisition advice code of l" or "f", the case must be evaluated locally where purchased or fabricated."
Air Force Flag

Air Force Management Code Definition

Fund A two position code that classifies an item into categories in terms of funding and budgeting.
Budget Identifies investment items to budget programs from which item is funded.
Material Management Identifies an item of supply to be managed by a specific activity manager.
Price Validation Indicates validity of the recorded unit price.
Similar parts: 5925-01-107-5040 5925-01-111-1311 5925-01-107-5065 5925-01-108-1677 5925-01-108-4238 5925-01-109-1868 5925-01-111-3373 5925-01-111-1315 5925-01-108-3572 5925-01-111-1309 5925-01-107-8010