Can't Find Your Part? Enter Your NSN or PART Number Here:

Last Modified: Dec 30, 2018

NSN 5925-00-004-5817 Circuit Breaker

MFG Part Numbers: M13516/8-6, M13516/8BII-175, AA55571/8, AA55571/08-001, 120932, 7855-7-175, 7855-7-175, MS39069-1, MIL-C-13516/8

Cross Reference Parts for NSN 5925-00-004-5817

MFG Part Number ISC RNVC RNCC HCC MSDS SADC DAC

M13516/8-6

5 9 5 3

M13516/8BII-175

5 1 4 E

AA55571/8

5 1 C A E

AA55571/08-001

5 9 5 E

120932

5 9 5 6

7855-7-175

5 2 2 6

7855-7-175

5 1 C A 5

MS39069-1

5 9 5 3

MIL-C-13516/8

5 1 5 E

Request A Quote

Part:
Qty:
Email:

Part Information for NSN 5925-00-004-5817 (5925000045817)

Item Name: CIRCUIT BREAKER
Federal Supply Class (FSC): 5925
NIIN: 00-004-5817 (000045817)
Definition: A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
NMF Description: CIRCUIT BREAKER/SWITCH NOI

Item Specifics

Federal Supply Class (FSC)
Circuit Breakers
Body Style
Single pole type AAQL
Body Width
2.120 inches nominal ADAT
Case Material
Plastic ADTV
Center To Center Distance Between Terminals Parallel To Length
1.485 inches minimum and 1.515 inches maximum AEBP
Circuit Protection Type
Overcurrent single location CPRH
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.500 inches nominal AEBY
Maximum Continuous Load Current Rating Per Pole
175.0 amperes dc single location CPLM
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location CPRG
Mounting Facility Type And Quantity
4 unthreaded hole AXHR
Mounting Surface To Terminal End Distance
2.220 inches nominal AJWX
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location CPRF
Fragility Factor
Moderately rugged AFJN
Storage Type
General purpose warehouse BBRG
Inclosure Protection Type For Which Designed
Vibration resistant and shock resistant and salt spray proof and fungus resistant CQXF
Internal Trip Release Configuration
Series trip single location CPSM
Reset Method
Automatic CPRQ
Overall Length
4.000 inches nominal ABHP
Pole Quantity
1 AKPX
Specification/standard Data
81349--13516/8bii government specification ZZZK
Terminal Type And Quantity
2 threaded stud TTQY
Test Data Document
81349-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). TEST
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location CQWN
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location CRCF
Trip Release Characteristic
Time delay single location CPRL
Trip Release Method
Thermal single location CPRJ
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location CPRN
Unthreaded Mounting Hole Diameter
0.218 inches nominal AEBV

Trade Control Compliance Schedule B Export Code: A ten position numeric code that identifies an item exported overseas. this unique identification code is assigned by the U.S. Census Bureau.

Schedule B Sch. B Description Demilitarization Classification ITAR Regulation
8536200040 Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9). Unclassified Not ITAR Controlled

MOE / End Users Represents the subdivisions of a US governmental organization or an agency of the North Atlantic Treaty Organization (NATO), and other friendly governments and international organizations participating in the federal catalog program.

Country / Entity Name MOE
Defense Logistics Agency
Defense Logistics Agency ZZ

Material & Special Handling Item material and handling information

Code Description Value Meaning
HMIRS P Indicates there is no information in the hmirs. the nsn is in a fsc in table ii of fed std 313 and a msds may be required by t
Precious Metals Indicator A Item does not contain precious metal.
Criticality Code X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

National Motor Freight NMFC: A six position numeric code, which divides articles into groups or classes according to physical characteristics. The classification is based on truckloads vs. less than truckload.

Code Description Code Value Meaning
NMF Description NMFC 061300 Circuit Breaker/switch Noi
Less than a truck load rating LTL P 77.5
Water Commodity WCC 658 Electrical appliances, small
Type of Cargo TCC Z No special type of cargo code applicable
Special Handling SHC 9 Other or no special handling required (sh)
Air Dimension Code ADC A Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity ACC H Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
Air Special Handling ASH Array No special handling required.

Item Identification | Circuit Breakers

5925-00-004-5817, A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Supply Class (FSC)NSN AssignmentNIINItem Name Code (INC)
5925 Jun 07, 1972 000045817 00136 (Circuit Breaker)

Circuit Breakers Cross Reference

120932 Cage Code 57633
AA55571/08-001 Cage Code 58536
AA55571/8 Cage Code 58536
7855-7-175 Cage Code 82647
7855-7-175 Cage Code 73803
M13516/8-6 Cage Code 81349
MS39069-1 Cage Code 96906
MIL-C-13516/8 Cage Code 81349
M13516/8BII-175 Cage Code 81349

Codes

COUNTRY CODE: 00
CIIC: U
DML: A
HMIC: P
MGMT CTRL: -------
SOS: SMS
INC: 136
WEAPON SYSTEM: SHIPBOARD MATERIAL HANDLING EQUIPMENT (MHE)
AAC: J
CRITL CODE: X
DEMIL CODE: A
S A: DN
MGMT CTL: 9B-----
NIIN ASGMT: 07-JUN-72
QUP: 0
SLC: 0
UI: EA
CAGE: 81349
RNCC: 5
RNVC: 9

Management

Navy Flag

Navy

Cognizance 9B – Naval inventory control point, mechanicsburg
Special Material
Requisition Restriction
Special Material Content
Navy Flag

Navy Management Code Definition

Cognizance (COG) Identifies the inventory manager (IM) and inventory control point (ICP).
Special Material (SMIC) Categorizes material on the basis of requirements for source or quality control, technical design, or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling
Req. Restriction (IRRC) Item requisition instructions.
Special Material (SMCC) Indicated that an item represents or contains peculiar material requiring special treatment, precautions, or management.
Similar parts: 5925-00-308-7141 5925-00-286-8502 5925-00-295-5460 5925-00-284-2713 5925-00-300-8984 5925-00-290-4326 5925-00-300-6352 5925-00-308-7152 5925-00-283-6511 5925-00-280-1238 5925-00-284-2714