Can't Find Your Part? Enter Your NSN or PART Number Here:

Last Modified: Mar 19, 2019

NSN 5925-00-016-3758 Circuit Breaker

MFG Part Numbers: G383729, G383729, G383729

Cross Reference Parts for NSN 5925-00-016-3758

MFG Part Number ISC RNVC RNCC HCC MSDS SADC DAC

G383729

2 9 3 A

G383729

2 9 5 A

G383729

2 9 5 5

Request A Quote

Part:
Qty:
Email:

Part Information for NSN 5925-00-016-3758 (5925000163758)

Item Name: CIRCUIT BREAKER
Federal Supply Class (FSC): 5925
NIIN: 00-016-3758 (000163758)
Definition: A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
NMF Description: CIRCUIT BREAKER/SWITCH NOI

Item Specifics

Federal Supply Class (FSC)
Circuit Breakers
Actuator Function
Trip-reset CPRW
Actuator Position Designation
At each pole CPRX
Body Length
2.530 inches nominal ADAQ
Body Style
Multipole-multiple actuator type AAQL
Body Width
2.280 inches nominal ADAT
Boss Height
0.130 inches nominal AJEC
Case Material
Plastic ADTV
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal AEBP
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal AEBQ
Circuit Protection Type
Overcurrent all locations CPRH
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal AEHA
External Actuator Linkage Arrangement
One, two, and three linked CPRY
Frequency In Hertz
60.0 third location FREQ
Frequency In Hertz
60.0 second location FREQ
Maximum Continuous Load Current Rating Per Pole
700.0 milliamperes dc first location CPLM
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac third location CPLM
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc first location CPRG
Mounting Facility Type And Quantity
6 threaded hole AXHR
Mounting Surface To Terminal End Distance
2.500 inches nominal AJWX
Nominal Thread Size
0.138 inches CQJX
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location CPRF
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc first location CPRF
Inclosure Protection Type For Which Designed
Fungus resistant CQXF
Internal Trip Release Configuration
Series trip all locations CPSM
Main Contact Tripping Mechanism Type
Trip free CPRR
Manual Actuator Type And Quantity
3 toggle CPRT
Reset Method
Manual CPRQ
Pole Quantity
3 AKPX
Storage Type
General purpose warehouse BBRG
Terminal Type And Quantity
6 threaded stud TTQY
Thread Quantity Per Inch
32 CMLP
Thread Series Designator
Unc THSD
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 nominal at 200 pct second location CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 nominal at 200 pct third location CQWN
Trip Release Characteristic
Instantaneous first location CPRL
Trip Release Method
Magnetic all locations CPRJ
Trip Release Characteristic
Time delay third location CPRL
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations CPRN

Trade Control Compliance Schedule B Export Code: A ten position numeric code that identifies an item exported overseas. this unique identification code is assigned by the U.S. Census Bureau.

Schedule B Sch. B Description Demilitarization Classification ITAR Regulation
8536200040 Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9). Unclassified Not ITAR Controlled

MOE / End Users Represents the subdivisions of a US governmental organization or an agency of the North Atlantic Treaty Organization (NATO), and other friendly governments and international organizations participating in the federal catalog program.

Country / Entity Name MOE
Department Of The Navy
Department Of The Navy ZZ

Material & Special Handling Item material and handling information

Code Description Value Meaning
HMIRS P Indicates there is no information in the hmirs. the nsn is in a fsc in table ii of fed std 313 and a msds may be required by t
Precious Metals Indicator U Precious metal content is unknown
Criticality Code X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

National Motor Freight NMFC: A six position numeric code, which divides articles into groups or classes according to physical characteristics. The classification is based on truckloads vs. less than truckload.

Code Description Code Value Meaning
NMF Description NMFC 061300 Circuit Breaker/switch Noi
Less than a truck load rating LTL P 77.5
Water Commodity WCC 658 Electrical appliances, small
Type of Cargo TCC Z No special type of cargo code applicable
Special Handling SHC 9 Other or no special handling required (sh)
Air Dimension Code ADC A Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity ACC H Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
Air Special Handling ASH Array No special handling required.

Item Identification | Circuit Breakers

5925-00-016-3758, A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Supply Class (FSC)NSN AssignmentNIINItem Name Code (INC)
5925 Jan 01, 1961 000163758 00136 (Circuit Breaker)

Circuit Breakers Cross Reference

G383729 Cage Code 74193
G383729 Cage Code 64959
G383729 Cage Code 01714

Codes

COUNTRY CODE: 00
CIIC: U
DML: A
HMIC: P
MGMT CTRL: 9N-----
SOS: S9E
INC: 136
AAC: Y
CRITL CODE: X
DEMIL CODE: A
S A: DN
MGMT CTL: 9N-----
NIIN ASGMT: 01-JAN-61
QUP: 1
SLC: 0
UI: EA
CAGE: 74193
RNCC: 3
RNVC: 9

Management

Navy Flag

Navy

Cognizance 9N – Naval inventory control point, mechanicsburg
Special Material
Requisition Restriction
Special Material Content
Navy Flag

Navy Management Code Definition

Cognizance (COG) Identifies the inventory manager (IM) and inventory control point (ICP).
Special Material (SMIC) Categorizes material on the basis of requirements for source or quality control, technical design, or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling
Req. Restriction (IRRC) Item requisition instructions.
Special Material (SMCC) Indicated that an item represents or contains peculiar material requiring special treatment, precautions, or management.
Similar parts: 5925-01-267-7763 5925-01-265-7743 5925-01-265-7709 5925-01-265-7706 5925-01-268-0426 5925-01-265-7729 5925-01-266-0843 5925-01-265-7720 5925-01-265-7715 5925-01-266-7142 5925-01-265-7738